Skip to main content
ABB 3AXD50000956784 — AC Drive (VFD) 480V

ABB 3AXD50000956784 ACH180 Micro Drive, 3.0 kW, 7.2 A

MPN3AXD50000956784
Active

ABB ACH180 series, 3AXD50000956784, LV AC micro drive module for HVAC, 3.0 kW / 7.2 A normal duty, 380-480 V, IP20, BACnet, IE2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Power & Output

3AXD50000956784 — Power & Output
ParameterValue
Output power, normal duty3.0 kW
Output current, normal duty7.2 A
Output power, heavy duty2.2 kW
Output current, heavy duty5.6 A
Output power, light overload3.0 kW
Output current, light overload6.8 A
Output current, light overload (UL rating)6.0 A
Apparent power output5.0 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)3.0 Hp
Standby power loss10 W

Input / Supply

3AXD50000956784 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz

Mechanical & Cooling

3AXD50000956784 — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule

Environmental

3AXD50000956784 — Environmental
ParameterValue
Temperature rating (max.)Maximum 60 °C

Electrical

3AXD50000956784 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)3.0 Hp
Technical UL/Output Current, Heavy-Duty Use (UL)4.8 A

Product details

The 3AXD50000956784: Input accepts 380-480 V at 47.5-63 Hz. Frame size is R1, module mounting. Enclosure is IP20 / NEMA Open Type, maximum ambient 60 °C, altitude 2000 m. Standby loss is 10 W; sound level 50.9 dB(A). Power factor is 0.98.

BACnet integration

Communication is BACnet only — no Industrial Ethernet interface on this variant. The drive has 2 analog inputs, 1 analog output, 4 digital inputs, and 2 digital outputs. For HVAC plants running BACnet MS/TP or BACnet/IP, this drive drops directly into the BMS bus without a gateway.

Frequently asked questions

What compliance documentation does this drive have?

RoHS compliant per EU Directive 2011/65/EU (dated 20240110), REACH declared (dated 20250905), SCIP number 5d07f008-496e-4abd-8f50-616cb485c791 Finland, and UL listed with ratings for normal, heavy-duty, and light-overload use.

What are the key output ratings?

Normal use: 3.0 kW / 7.2 A (IEC), 3.0 Hp / 6.0 A (UL). Heavy-duty: 2.2 kW / 5.6 A (IEC), 3.0 Hp / 4.8 A (UL). Light-overload: 3.0 kW / 6.8 A (IEC), 3.0 Hp / 6.0 A (UL). Apparent power: 5.0 kV·A.

What communication protocol does it use?

BACnet only — no Industrial Ethernet interface on this variant.

What is the input voltage and frequency range?

380-480 V, 47.5-63 Hz, three-phase.

MPN