ABB 3AXD50001002756 — AC Drive (VFD) 480V

3AXD50001002756 ABB ACH580-01-018A-4+B063 7.5 kW VFD, IP66,

MPN3AXD50001002756
Active

ABB ACH580-01-018A-4+B063, LV AC wall-mounted drive for HVAC, IEC: Pn 7.5 kW, 17 A, 400 V, UL: Pld 10 Hp, 14 A, 500 V, IP66, NEMA 4X, frame R2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50001002756 — Power & Output
ParameterValue
Output power, normal duty7.5 kW
Output current, normal duty17 A
Output power, heavy duty5.5 kW
Output current, heavy duty12.6 A
Output power, light overload7.5 kW
Output current, light overload16.2 A
Output current, light overload (UL rating)14 A
Apparent power output11.8 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)10 Hp
Standby power loss15 W
3AXD50001002756 — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50001002756 — Mechanical & Cooling
ParameterValue
Frame sizeR2
NEMA enclosure typeType4X
Degree of protection (IP)IP66
Mounting typeWall-mounted
3AXD50001002756 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The ABB 3AXD50001002756 is the order code for a wall-mounted drive sized for a 7.5 kW motor on a 380–415 V three-phase supply, delivering 17 A continuous in normal use. The IP66 / NEMA 4X enclosure makes it a direct mount in washdown or outdoor HVAC zones without a separate cabinet — the standby loss of 15 W stays inside the sealed box, so verify ambient stays under 40 °C on the back of the panel.

Heavy-duty use derates the drive to 5.5 kW / 12.6 A; light-overload use holds at 7.5 kW but drops the current ceiling to 16.2 A. The UL light-overload line is 10 Hp at 14 A.

Frame R2 is a wall-mount package. The control unit is included — no separate controller module to order. Two analog inputs and two analog outputs are on board; digital I/O counts six inputs and three outputs. BACnet is the built-in fieldbus; there is no second Ethernet interface, so if the site runs Modbus TCP or PROFINET, a separate option card is required. The lithium coin cell (CR2032, 220 mAh) keeps the real-time clock alive through power loss.

Frequently asked questions

What communication protocol does this drive support?

BACnet is the built-in protocol. The drive has no second industrial Ethernet interface, so a different fieldbus requires an option card.

What is the ambient temperature limit for this drive?

The maximum ambient temperature rating is 40 °C. Above that, derating applies per the thermal curve.

MPN
3AXD50001002756