Skip to main content
ABB 3AXD50001002947 — AC Drive (VFD) 480V

ABB 3AXD50001002947 ACQ580-01 Drive, 5.5 kW, IP66

MPN3AXD50001002947
Active

ABB ACQ580-01 series, LV AC wall-mounted drive, 3AXD50001002947, 5.5 kW / 12.6 A, IP66, NEMA 4X.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50001002947 — Power & Output
ParameterValue
Output power, normal duty5.5 kW
Output current, normal duty12.6 A
Output power, heavy duty4 kW
Output current, heavy duty9.4 A
Output power, light overload5.5 kW
Output current, light overload12 A
Output current, light overload (UL rating)12 A
Apparent power output8.7 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)8 Hp
Standby power loss14 W
3AXD50001002947 — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50001002947 — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeType4X
Degree of protection (IP)IP66
Mounting typeWall-mounted
3AXD50001002947 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The ABB 3AXD50001002947 is an LV AC wall-mounted drive, frame size R1, rated 5.5 kW normal-use output at 12.6 A on a 400 V three-phase supply. It is built for water and wastewater applications, with an IP66 / NEMA 4X enclosure that handles washdown environments without an extra cabinet. The drive includes the control unit, so it arrives ready for commissioning — no separate controller module to order.

Heavy-duty use (PhD) drops to 4 kW at 9.4 A — that is the rating to size against for constant-torque loads like screw feeders or positive-displacement pumps. Light-overload use (PlD) matches the normal-use power but at 12 A, slightly below the normal-use current, so the drive can handle occasional overloads without tripping. The power factor of 0.98 means the input current draw is nearly in phase with voltage, which keeps distribution losses low. Standby loss of 14 W is the heat the drive dissipates when the motor is stopped — relevant for panel ventilation in a sealed NEMA 4X installation.

Integration notes

Mounts on a wall via the R1 frame's integral mounting points. Two analog inputs and two analog outputs are available for process signals.

Frequently asked questions

What does 'Includes Control unit' mean on this order code?

The drive ships with the control unit integrated — no separate controller module purchase is needed. It is ready for commissioning out of the box.

What is the frame size of this drive?

Frame size R1. This determines the physical dimensions, mounting hole pattern, and the maximum wire size that fits the power terminals.

MPN
3AXD50001002947