Skip to main content
ABB 3AXD50001002985 — AC Drive (VFD) 480V

ABB 3AXD50001002985 ACQ580-01 Drive, 18.5 kW, IP66

MPN3AXD50001002985
Active

ABB ACQ580-01 wall-mounted drive, 3AXD50001002985, frame R3, 18.5 kW / 38 A normal use, IP66, NEMA 4X, includes control unit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50001002985 — Power & Output
ParameterValue
Output power, normal duty18.5 kW
Output current, normal duty38 A
Output power, heavy duty15 kW
Output current, heavy duty31.6 A
Output power, light overload18.5 kW
Output current, light overload36.1 A
Output current, light overload (UL rating)34 A
Apparent power output26.3 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)25 Hp
Standby power loss16 W
3AXD50001002985 — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50001002985 — Mechanical & Cooling
ParameterValue
Frame sizeR3
NEMA enclosure typeType4X
Degree of protection (IP)IP66
Mounting typeWall-mounted
3AXD50001002985 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The 3AXD50001002985: Normal-use output is 18.5 kW / 38 A; heavy-duty use is 15 kW / 31.6 A. For a water pump running a steady load curve, the normal-use figure governs. For a lift station with periodic overloads, the heavy-duty rating is the one to spec against — it gives headroom without oversizing the frame. Enclosure is IP66 / NEMA 4X, so the drive is rated for washdown environments and outdoor installation without an extra cabinet. Ambient maximum is 40 °C — derate above that, but for most water/wastewater sites that's the standard operating range. Communication is CAN-based; no onboard Ethernet. If the site uses Modbus TCP or PROFINET, plan for an external gateway or a different drive variant. The 6 digital inputs and 3 digital outputs, plus 2 analog inputs and 2 analog outputs, cover typical pump control — start/stop, speed reference, feedback. Standby loss is 16 W — negligible for energy budgeting but worth noting if the drive is on a UPS-backed circuit. Power factor is 0.98, so line-side filtering is minimal.

Frequently asked questions

What does this order code include?

It includes the control unit. This is a complete drive, not a bare power stage — you get the control board and firmware as part of the assembly.

What is the frame size?

Frame R3. This determines mounting hole pattern, conduit entry locations, and physical footprint for panel layout or wall mounting.

What enclosure protection does it have?

IP66 and NEMA 4X. Suitable for outdoor, washdown, or dusty environments without an additional enclosure.

MPN
3AXD50001002985