Skip to main content
ABB 3AXD50001003111 — AC Drive (VFD) 480V

ABB 3AXD50001003111 ACS580-01 VFD, 2.2 kW, IP66

MPN3AXD50001003111
Active

ABB ACS580-01 series, LV AC industrial wall-mounted single drive, 2.2 kW / 5.6 A, 400 V, IP66, NEMA 4X, frame size R1, includes control unit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50001003111 — Power & Output
ParameterValue
Output power, normal duty2.2 kW
Output current, normal duty5.6 A
Output power, heavy duty1.5 kW
Output current, heavy duty4 A
Output power, light overload2.2 kW
Output current, light overload5.3 A
Output current, light overload (UL rating)4.8 A
Apparent power output3.9 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)3 Hp
Standby power loss14 W
3AXD50001003111 — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50001003111 — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeType4X
Degree of protection (IP)IP66
Mounting typeWall-mounted
3AXD50001003111 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The ABB 3AXD50001003111 is a wall-mounted drive rated for 2.2 kW normal-use output at 5.6 A on a 380–415 V three-phase supply. It ships with the control unit included. Frame size R1 keeps the footprint compact for panel or wall mounting, and the IP66 / NEMA 4X enclosure means it can sit directly on the machine or in a washdown area without an extra cabinet. Ambient limit is 40 °C, so watch the air flow if you pack several in a row. The drive carries IE2 efficiency and a power factor of 0.98, which keeps the line-side losses low for continuous-duty applications. Standby loss sits at 14 W — not negligible if the drive stays powered but idle for long periods.

Normal-use output (Pn) is 2.2 kW at 5.6 A — that's the rating for typical constant-torque loads like conveyors or fans running within the drive's continuous current capability. Heavy-duty use (PhD) drops to 1.5 kW at 4 A, which is the headroom you need for high-starting-torque applications or overload cycles. Light-overload use (PlD) stays at 2.2 kW but at 5.3 A, slightly below the normal-use current, reflecting a different duty cycle definition. Under UL listing, the light-overload output is 3 Hp at 4.8 A — close to the IEC light-overload figure but not identical, so match the rating system your local code requires. Apparent power output is 3.9 kV·A. Frequency range is 47.5 to 63 Hz.

I/O and communication — what's on board

The control unit provides 2 analog inputs, 2 analog outputs, and 6 digital inputs plus 3 digital outputs. That's enough for basic speed reference, feedback, and start/stop logic without an expansion module. Communication is CAN-based — no onboard Industrial Ethernet, so if you need PROFINET or EtherNet/IP, plan for an optional fieldbus adapter. A CR2032 lithium coin cell (220 mAh, 3 V) backs the real-time clock and parameter storage. It's a standard cell, easy to replace during maintenance.

Frequently asked questions

What is the frame size of this drive?

Frame size R1, which is the smallest frame in the ACS580-01 series, suitable for wall mounting.

Does the drive include a control unit?

Yes, the control unit is included with the 3AXD50001003111 order code. No separate purchase is needed for basic I/O and CAN communication.

What enclosure rating does it have?

IP66 and NEMA 4X, suitable for washdown environments and outdoor installation without an additional cabinet.

What are the key output ratings?

Normal-use: 2.2 kW at 5.6 A. Heavy-duty: 1.5 kW at 4 A. Light-overload: 2.2 kW at 5.3 A (IEC) or 3 Hp at 4.8 A (UL).

MPN
3AXD50001003111