ABB 3AXD50001003135 — AC Drive (VFD) 480V

ABB 3AXD50001003135 ACS580-01 Drive, 4 kW, 9.4 A, IP66

MPN3AXD50001003135
Active

ABB ACS580-01 wall-mounted drive, 4 kW normal use, 9.4 A, 380-415 V, IP66, NEMA 4X, frame R1, includes control unit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50001003135 — Power & Output
ParameterValue
Output power, normal duty4 kW
Output current, normal duty9.4 A
Output power, heavy duty3 kW
Output current, heavy duty7.2 A
Output power, light overload4 kW
Output current, light overload8.9 A
Output current, light overload (UL rating)6.0 A
Apparent power output6.5 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)3 Hp
Standby power loss14 W
3AXD50001003135 — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50001003135 — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeType4X
Degree of protection (IP)IP66
Mounting typeWall-mounted
3AXD50001003135 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

Integrator's field note

The ABB 3AXD50001003135 is a wall-mounted drive in frame R1, rated 4 kW normal use (9.4 A) on 380–415 V three-phase. The IP66 / NEMA 4X enclosure means it can sit directly on the machine frame or washdown area — no separate cabinet needed. Two analog inputs and two analog outputs are on board; digital I/O counts six inputs and three outputs. Communication is CAN only, so if the line uses Ethernet, plan on an external gateway or a different drive variant.

Duty ratings

Normal-use output is 4 kW / 9.4 A. Heavy-duty use drops to 3 kW / 7.2 A. Light-overload use is 4 kW / 8.9 A. UL light-overload rating is 3 Hp / 6.0 A at 500 V.

Wall-mounted, frame R1. Ambient temperature limited to 40 °C maximum. Standby loss is 14 W — negligible for panel heat calculations but worth noting for sealed enclosures. Power factor is 0.98.

Frequently asked questions

What are the key ratings for this drive?

Normal-use output is 4 kW / 9.4 A at 380–415 V three-phase. Heavy-duty output is 3 kW / 7.2 A. Enclosure is IP66 / NEMA 4X. Frame size is R1.

What communication protocol does this drive support?

CAN is the listed communication protocol; there are no industrial Ethernet interfaces.

MPN