ABB 3AXD50001062606 — AC Drive (VFD) 480V

3AXD50001062606 ABB ACS580-01-089A-4 45 kW Drive, 89 A, IP21

MPN3AXD50001062606
Active

ABB ACS580-01-089A-4, LV AC general-purpose wall-mounted drive, 45 kW / 89 A normal duty, 380–480 V 3-phase, IP21, R4 frame.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50001062606 — Power & Output
ParameterValue
Output power, normal duty45 kW
Output current, normal duty89 A
Output power, heavy duty37 kW
Output current, heavy duty72 A
Output power, light overload45 kW
Output current, light overload83 A
Apparent power output62 kV·A
Efficiency class (IE)IE2
Standby power loss21 W
3AXD50001062606 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50001062606 — Mechanical & Cooling
ParameterValue
Frame sizeR4
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeWall-mounted
3AXD50001062606 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The ABB 3AXD50001062606 is the order code for an ACS580-01-089A-4 wall-mounted general-purpose drive. Input accepts 380–480 V 3-phase, 47.5–63 Hz. Frame size R4, IP21, NEMA Type 1 enclosure — suitable for indoor panel or wall mounting without additional filtration in clean environments.

Output ratings and duty cycles

Three duty ratings are listed: light-overload use at 45 kW / 83 A, normal use at 45 kW / 89 A, and heavy-duty use at 37 kW / 72 A. The heavy-duty figure governs constant-torque applications; the normal-use current (89 A) is the one to match against motor FLA for variable-torque loads like pumps and fans. Apparent power output is 62 kV·A at the rated voltage.

Efficiency and losses

Efficiency Level IE2, with standby loss of 21 W and power consumption at rated output of 1028 W. The standby figure matters for panel heat-budget calculations — 21 W continuous keeps the enclosure rise modest, but the full-load dissipation pushes 1 kW, so forced ventilation is worth planning for in a sealed cabinet.

Includes a control unit with 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs. Communication is CAN-based — no onboard Industrial Ethernet. For PROFINET or EtherNet/IP, you would add an optional fieldbus adapter module. The lithium coin cell (CR2032, 220 mAh) backs the real-time clock and parameter storage.

Frequently asked questions

What are the key output ratings for this drive?

Normal-duty output is 45 kW at 89 A; heavy-duty output is 37 kW at 72 A; light-overload output is 45 kW at 83 A. Apparent power output is 62 kV·A.

What is the enclosure rating and mounting style?

IP21, NEMA Type 1, wall-mounted. Frame size R4.

What communication protocol does this drive use?

CAN protocol. No onboard Industrial Ethernet; a fieldbus adapter is required for PROFINET or EtherNet/IP.

MPN
3AXD50001062606