ABB 3AXD50001109356 — AC Drive (VFD) 480V

ABB 3AXD50001109356 ACS580-01 Drive, 5.5 kW, IP66

MPN3AXD50001109356
Active

ABB ACS580-01 series, LV AC industrial wall-mounted single drive, 3AXD50001109356, 5.5 kW / 7.5 Hp, 12.6 A, IP66, Type 4X.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50001109356 — Power & Output
ParameterValue
Output power, normal duty5.5 kW
Output current, normal duty12.6 A
Output power, heavy duty4 kW
Output current, heavy duty9.4 A
Output power, light overload5.5 kW
Output current, light overload12 A
Output current, light overload (UL rating)12 A
Apparent power output8.7 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)7.5 Hp
Standby power loss14 W
3AXD50001109356 — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50001109356 — Mechanical & Cooling
ParameterValue
NEMA enclosure typeType4X
Degree of protection (IP)IP66
Mounting typeWall-mounted
3AXD50001109356 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The 3AXD50001109356: The enclosure is IP66 / NEMA Type 4X, rated for washdown and outdoor installation. Ambient temperature max is 40 °C. Standby loss is 14 W. Power factor is 0.98. Includes a control unit with 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs. Communication is via CAN; no onboard industrial Ethernet. A lithium coin cell (CR2032, 220 mAh) backs the real-time clock.

Frequently asked questions

What are the key output ratings for this drive?

Normal-use output is 5.5 kW at 12.6 A; heavy-duty use is 4 kW at 9.4 A; light-overload use is 5.5 kW at 12 A. UL light-overload rating is 7.5 Hp at 12 A.

What enclosure protection does this drive offer?

IP66 and NEMA Type 4X, suitable for washdown and outdoor installation. Maximum ambient temperature is 40 °C.

What communication protocol does the control unit support?

CAN communication is standard. There is no onboard industrial Ethernet interface.

MPN