Ratings and duty classes
The 3AXD50001109547: Three duty curves are defined: normal-use (Pn 3 kW, In 7.2 A), heavy-duty (PhD 2.2 kW, IhD 5.6 A), and light-overload (PlD 3 kW, IlD 6.8 A). Under UL the light-overload rating is 5 Hp at 7.6 A. The power factor sits at 0.98, and standby loss is 14 W.
The drive includes 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs. Communication is over CAN; there is no onboard industrial Ethernet interface. A CR2032 lithium coin cell (220 mAh, 3 V) backs the real-time clock and parameter storage.
Environmental limits
Rated for a maximum ambient temperature of 40 °C and an input frequency range of 47.5…63 Hz. Efficiency class is IE2.