Skip to main content
ABB 3AXD50001109714 — AC Drive (VFD) 480V

ABB 3AXD50001109714 ACH580-01 HVAC Drive, 0.75 kW, IP66

MPN3AXD50001109714
Active

ABB 3AXD50001109714, ACH580-01 series, LV AC wall-mounted HVAC drive, 0.75 kW, 2.6 A, 400 V, IP66, BACnet communication.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50001109714 — Power & Output
ParameterValue
Output power, normal duty0.75 kW
Output current, normal duty2.6 A
Output power, heavy duty0.6 kW
Output current, heavy duty1.8 A
Output power, light overload0.75 kW
Output current, light overload2.5 A
Output current, light overload (UL rating)2.1 A
Apparent power output1.8 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)1 Hp
Standby power loss14 W
3AXD50001109714 — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50001109714 — Mechanical & Cooling
ParameterValue
NEMA enclosure typeType4X
Degree of protection (IP)IP66
Mounting typeWall-mounted
3AXD50001109714 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The ABB 3AXD50001109714 is a wall-mounted LV AC drive from the ACH580-01 series, sized for HVAC applications at 0.75 kW normal-use output and 2.6 A on a 400 V three-phase supply. It includes a control unit and communicates over BACnet, which is the standard protocol for building automation integration. The IP66 enclosure and NEMA Type 4X rating let it mount directly on the wall in washdown or dusty environments without a separate cabinet — a common ask for rooftop units or pump rooms.

Ratings and fit for the load

The normal-use current of 2.6 A at 400 V maps to a standard 0.75 kW IEC motor. The light-overload rating matches the normal-use power at 0.75 kW but pulls 2.5 A — close to the normal-use figure, so the drive is not significantly oversized for variable-torque fan or centrifugal pump curves. The UL light-overload rating is 1 Hp at 2.1 A on 500 V, so the same drive works on North American 480 V systems without derating.

Installation notes

Wall-mounted, IP66, NEMA 4X — the drive is self-contained for outdoor or washdown installs. Ambient temperature is rated to 40 °C maximum, so derate if the enclosure sits in direct sun or a hot mechanical room. The standby loss of 14 W matters for energy calculations on continuously powered HVAC systems. The power factor of 0.98 is the drive-side input, not the motor-side; it reflects the active front-end or diode-bridge design typical of this class.

Frequently asked questions

What does the order code include?

The listing includes a control unit. The drive is supplied as a complete wall-mounted unit with the BACnet communication interface.

What is the power factor of this drive?

The power factor is listed at 0.98. This is the input-side power factor, typical for a drive with an active rectifier or a well-filtered diode bridge.

MPN