ABB 3AXD50001109790 — AC Drive (VFD) 480V

ABB 3AXD50001109790 ACH580 HVAC Drive, 11 kW, 25 A, IP66

MPN3AXD50001109790
Active

ABB ACH580-01 series, LV AC wall-mounted HVAC drive, 3AXD50001109790, 11 kW / 25 A normal duty, IP66, NEMA 4X, BACnet.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50001109790 — Power & Output
ParameterValue
Output power, normal duty11 kW
Output current, normal duty25 A
Output power, heavy duty7.5 kW
Output current, heavy duty17 A
Output power, light overload11 kW
Output current, light overload23.8 A
Output current, light overload (UL rating)23 A
Apparent power output17.3 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)15 Hp
Standby power loss15 W
3AXD50001109790 — Input / Supply
ParameterValue
Input voltage range380 ... 415 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50001109790 — Mechanical & Cooling
ParameterValue
NEMA enclosure typeType4X
Degree of protection (IP)IP66
Mounting typeWall-mounted
3AXD50001109790 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

Normal-use output current is 25 A (In) — that's the continuous rating for a standard pump or fan load. Light-overload use (PlD) also runs at 11 kW but draws 23.8 A, slightly less headroom. Heavy-duty use (PhD) drops to 7.5 kW / 17 A, which is the rating to use if the load cycles hard or runs near full torque at low speed. The UL light-overload line is 15 Hp at 23 A, 500 V — match that to your local code if the job is under NEC. Standby loss is 15 W — negligible for energy tracking but worth noting if the drive sits on a UPS-backed circuit. Efficiency is IE2 class, which is the baseline for HVAC drives in most markets; no premium-efficiency adder here.

I/O and fieldbus for the controls integrator

The drive carries 2 analog inputs and 2 analog outputs — enough for a speed reference from a BMS and a feedback signal. Digital I/O counts 6 inputs and 3 outputs, which covers start/stop, fault reset, and a run-status relay back to the controller. Communication is BACnet out of the box; no option card needed for BAS integration. The control unit is included, so the drive ships ready to commission — no separate control panel to order. The lithium coin cell (CR2032, 220 mAh) keeps the real-time clock alive through a power loss.

That means this order code is still the current production variant for the ACH580-01 11 kW IP66 BACnet configuration. No successor to track; no cross-reference needed.

Frequently asked questions

What does the IP66 rating mean for installation?

IP66 and NEMA 4X mean the drive is dust-tight and protected against hose-directed water and corrosion. It mounts directly on a wall or rooftop without an extra enclosure — suitable for food processing washdowns, chemical plants, and outdoor HVAC units.

What communication protocol does this drive use?

BACnet is the onboard protocol, so it connects directly to building automation systems without an add-on gateway or option card.