ABB ACH180 series LV AC micro drive, 3AXD50001110116, 0.75 kW / 2.6 A normal use, 380-480 V three-phase, BACnet, IP20, frame R0.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3AXD50001110116 — Power & Output
ParameterValue
Output power, normal duty0.75 kW
Output current, normal duty2.6 A
Output power, heavy duty0.55 kW
Output current, heavy duty1.8 A
Output power, light overload0.75 kW
Output current, light overload2.5 A
Output current, light overload (UL rating)2.1 A
Apparent power output1.8 kV·A
Output power, light overload (UL rating, Hp)1 Hp
3AXD50001110116 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50001110116 — Mechanical & Cooling
ParameterValue
Frame sizeR0
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3AXD50001110116 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)0.75 Hp
Technical UL/Output Current, Heavy-Duty Use (UL)1.6 A

Product details

The ABB 3AXD50001110116 is a BACnet-native micro drive sized for a 0.75 kW induction motor on 380-480 V three-phase. Normal-use output is 2.6 A; heavy-duty use drops to 0.55 kW and 1.8 A for constant-torque loads. Light-overload use matches normal-use power at 0.75 kW but with a 2.5 A current limit. Frame size R0 keeps the footprint small — module mounting, IP20, so it lives inside a panel. The control unit is included, meaning you get the keypad and basic I/O out of the box: 2 analog inputs, 1 analog output, 4 digital inputs, 2 digital outputs. Power consumption is 29 W at rated load, and the apparent power output is 1.8 kVA.

Integration notes

BACnet MS/TP is the built-in fieldbus — no option card needed for HVAC integration. The frequency range is 47.5 to 63 Hz, so it handles 50 Hz and 60 Hz mains without derating. Altitude rating is 2000 m; above that, derate per the datasheet's thermal curve. Open-type NEMA enclosure means it's not standalone — install in a suitable cabinet.

Frequently asked questions

What are the key output ratings for this drive?

Normal-use output is 0.75 kW at 2.6 A; heavy-duty use is 0.55 kW at 1.8 A; light-overload (variable-torque) is 0.75 kW at 2.5 A. UL ratings are 1 Hp / 2.1 A for normal and light-overload, 0.75 Hp / 1.6 A for heavy-duty.

What communication protocol does this drive support?

BACnet MS/TP is the onboard protocol — no additional module required for building automation integration.