Skip to main content
ABB 3AXD50001158873 — AC Drive (VFD) 480V

ABB 3AXD50001158873 ACS580-07 Drive, 45 kW, 89 A, 400 V

MPN3AXD50001158873
Active

ABB ACS580-07 cabinet-built drive, 3AXD50001158873, 45 kW normal use, 89 A, 400 V, IP21, frame R4.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50001158873 — Power & Output
ParameterValue
Output power, normal duty45 kW
Output current, normal duty89 A
Output power, heavy duty37 kW
Output current, heavy duty72 A
Output power, light overload45 kW
Output current, light overload83 A
Output current, light overload (UL rating)77 A
Apparent power output62 kV·A
Output power, light overload (UL rating, Hp)60 Hp
3AXD50001158873 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50001158873 — Mechanical & Cooling
ParameterValue
Frame sizeR4
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeCabinet-built
3AXD50001158873 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C
3AXD50001158873 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)50 Hp
Technical UL/Output Current, Heavy-Duty Use (UL)65 A

Product details

The ABB 3AXD50001158873 is an ACS580-07 cabinet-built drive rated for 45 kW normal use (89 A) at 400 V three-phase input, with heavy-duty capability of 37 kW (72 A). It ships as a complete unit including the control module, mounted in an IP21 Type 1 enclosure, frame size R4.

The normal-use rating of 45 kW / 89 A is the headline number for continuous motor duty. Heavy-duty use drops to 37 kW / 72 A — that is the rating to size against when the load profile includes sustained overloads or high starting torque. Light-overload use is rated at 45 kW / 83 A, which sits between normal and heavy-duty curves. For UL installations, the heavy-duty output is 50 Hp / 65 A, and light-overload is 60 Hp / 77 A. The drive accepts 380–480 V three-phase at 47.5–63 Hz.

The control unit provides 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs. Communication is via CAN; there is no onboard industrial Ethernet interface. The drive includes a CR2032 lithium coin cell for real-time clock backup.

The 3AXD50001158873 carries an active lifecycle status. No last-time-buy or successor notice applies.

Frequently asked questions

What is the frame size of this drive?

Frame size R4.

What is included with the drive?

The drive includes a control unit as standard.

MPN
3AXD50001158873