Schneider Electric A9C15181

Schneider Electric A9C15181 Acti9 CT Contactor, 2P, 25 A, 23

MPN A9C15181
Obsolete

Schneider Electric Acti9 CT contactor, A9C15181, 2P, 25 A AC-7A / 8.5 A AC-7B, 230 V AC 50 Hz coil, clip-on 35 mm DIN rail, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9C15181 key specifications
ParameterValue
Control typeRemote and manual control
Control signal typeMaintained
Main product or component typeContactor
Voltage250 V AC 50 Hz
Coil voltage230 V AC 50 Hz
Insulation voltage ui500 V AC
Current25 A AC-7 A 8.5 A AC-7B
Frequency100 switching operations/day
Poles2P
Utilization categoryAC-1 conforming to IEC 60947-4
Temp storage max60 °C
Temp storage min-40 °C

All specifications

A9C15181 additional specifications
ParameterValue
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...60 °C
Pollution degree2
ColorWhite
Depth66 mm
Width18 mm
Height90 mm
Mechanical life cycles200000 cycles
ApplicationControl circuit
Operating temperature-5...60 °C

Product details

It clips onto a 35 mm symmetrical DIN rail and is rated for 25 A in AC-7A duty (resistive loads like lighting) and 8.5 A in AC-7B duty (inductive loads like small motors). The coil pulls 230 V AC at 50 Hz, with an inrush of 15 VA and a holding power of 3 W at 250 V AC. The 2 NO pole composition means both poles are normally open — it makes the circuit when the coil is energised. That fits standard control schemes where the contactor isolates the load until commanded. The maintained control signal type means it stays latched as long as coil voltage is present; no pulse or self-latching logic required.

The 18 mm width (one modular pitch) and 90 mm height let it sit neatly in a DIN-rail enclosure alongside other Acti9 devices. Two 9 mm pitches on the housing align with standard busbar systems for power distribution. The clip-on mounting means no tools for rail attachment — push on, pull off with a screwdriver tab. Terminals are tunnel type: power circuit accepts up to 2 x 2.5 mm² flexible or 1 x 6 mm² rigid; control circuit accepts 2 x 2.5 mm² flexible or 2 x 1.5 mm² rigid. Strip length is 10 mm, tightening torque 0.8 N·m.

The utilisation category AC-1 per IEC 60947-4 covers resistive loads — heaters, incandescent lighting, non-inductive banks — up to the full 25 A. For motor or inductive loads (AC-7B), the rated operational current drops to 8.5 A. That's the figure to use when sizing for a small fan or pump contactor; the AC-1 number is only for purely resistive circuits. Pollution degree 2 (non-conductive dust, occasional condensation) is typical for enclosed panels. The 2000 m operating altitude covers most installations; above that, derating applies per IEC standards. Mechanical durability is 200,000 cycles — the contactor is rated for that many operations before mechanical wear is expected. Switching frequency is 100 operations per day, which matches the on-load factor of 100 % (continuous duty, 86400 s). That means it can stay energised indefinitely without overheating, as long as the load stays within the rated current.