Skip to main content
Schneider Electric A9C52340

A9C52340 Reflex iC60N 40A 3P C-curve MCB, 20kA

MPN A9C52340
Obsolete

Schneider Electric Acti9 Reflex iC60N integrated control circuit breaker, 40 A, 3P, curve C, 20 kA breaking capacity.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9C52340 specifications
ParameterValue
Trip unit typeThermal-magnetic
Control signal typeMaintained Impulse
Main product or component typeIntegrated control circuit breaker
Coil voltage230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC
Insulation voltage ui500 V AC
IP ratingIP20
Pollution degree3
ColorWhite
Depth77 mm
Width99 mm
Height84 mm
Electrical life cyclesAC-1: 50000 cycles AC 50 Hz
Mechanical life cycles50000 cycles
ApplicationControl Distribution

Product details

The Schneider Electric A9C52340 is a Reflex iC60N integrated control circuit breaker from the Acti9 range — a 3-pole, 40 A thermal-magnetic MCB with a C-curve trip characteristic, designed for control and distribution applications on AC networks at 50/60 Hz. It mounts on a 35 mm symmetrical DIN rail, fixed position, and occupies 11 x 9 mm pitches (99 mm width) — standard panel footprint for a 3P device.

Control and signalling

The control circuit accepts multiple voltages: 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC — so it works with both AC and DC control systems common in industrial panels. Control is by maintained or impulse signal, with a toggle ON/OFF button and remote pulse capability. Local signalling includes a green LED for ON, red for fault, flashing for trip or overheat — gives a quick visual on the panel door without opening the enclosure. A contact position indicator and padlock provision (OFF position) support lockout/tagout procedures.

Integration notes

IP20 rated per IEC 60529 — suitable for dry indoor enclosures only; not for washdown or outdoor use. Earth-leakage protection requires a separate block (not integrated), so plan for an external RCCB or RCBO if ground-fault protection is needed. Electrical durability is 50,000 cycles at AC-1 (resistive load) — fine for frequent switching in lighting or distribution panels. Mechanical durability matches at 50,000 cycles.

MPN
A9C52340