Skip to main content
Schneider Electric A9C61340

Schneider Electric A9C61340 Reflex iC60N 40A 3P Curve B MCB

MPN A9C61340
Obsolete

Schneider Electric Acti9 Reflex iC60N integrated control MCB, A9C61340, 40 A, 3P, curve B, 20 kA breaking capacity, 230 V AC control.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9C61340 specifications
ParameterValue
Trip unit typeThermal-magnetic
Main product or component typeIntegrated control circuit breaker
Coil voltage230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC
Insulation voltage ui500 V AC
Breaking capacity20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Pollution degree3
ColorWhite
Depth77 mm
Width99 mm
Height84 mm
Electrical life cyclesAC-1: 50000 cycles AC 50 Hz
Mechanical life cycles50000 cycles
ApplicationControl Distribution

Product details

The 20 kA breaking capacity at 230 V AC (10 kA at 380–415 V) means it can safely interrupt a serious fault without upstream devices having to clear it. The control circuit accepts 230 V AC, 24 V AC, 48 V AC, 24 V DC, or 48 V DC, and supports maintained, impulse, or toggle commands. That's the flexibility you need when tying into a PLC output or a manual pushbutton station — no extra interface relay required for most common signal levels.

Takes 11 x 9 mm pitches of rail space — call it 99 mm wide, 84 mm tall, 77 mm deep. That's a standard 3-module footprint for the Acti9 family, so it slots into a distribution board without surprises. IP20 rated, so it's for inside an enclosure, not on the wet side of the panel door. The tropicalisation class 2 adds some margin for high-humidity storage or operation — 93% RH at 40 °C is the listed limit.

The B curve means the magnetic trip threshold is 3–5 times rated current (120–200 A for this 40 A unit). That's the standard choice for general distribution and control circuits — it won't false-trip on motor inrush, but it clears fast on a hard short. The thermal-magnetic trip technology is the workhorse for this class; no electronics to fail, no auxiliary power needed for the protection function. Electrical durability is 50,000 cycles under AC-1 resistive load at 50 Hz. That's the same as the mechanical endurance, so the switch mechanism is the limiting factor, not the contacts. For a control breaker that sees daily remote switching, that's a solid service life before you'd plan a replacement.

MPN
A9C61340