Skip to main content
Schneider Electric A9C64416

Schneider Electric A9C64416 Reflex iC60H Ti24 16A 4P Curve B

MPN A9C64416
Obsolete

Schneider Electric Acti9 Reflex iC60H Ti24, A9C64416, integrated control MCB, 16 A, 4P, curve B, 30 kA Icu at 230 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9C64416 specifications
ParameterValue
Trip unit typeThermal-magnetic
Main product or component typeIntegrated control circuit breaker
Coil voltage230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC
Insulation voltage ui500 V AC
Breaking capacity30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Pollution degree3
ColorWhite
Depth77 mm
Width117 mm
Height84 mm
Electrical life cyclesAC-1: 50000 cycles AC 50 Hz
Mechanical life cycles50000 cycles
ApplicationControl Distribution

Product details

Integrated control circuit breaker for panel-based distribution

The Schneider Electric A9C64416 is a Reflex iC60H Ti24 integrated control circuit breaker from the Acti9 range, combining overcurrent protection with local and remote switching in a single 4-pole unit. Rated 16 A with a B curve, it is designed for control distribution panels where you need both a disconnecting means and motor/load switching under one DIN-rail footprint.

The 30 kA Icu at 230 V AC (15 kA at 415 V AC) per EN/IEC 60947-2 tells you this breaker can interrupt a fault up to that level without welding its contacts — critical for panel SCCR coordination. Control voltage options span 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC, with three control signal types (maintained very low voltage, impulse, maintained). This means the same part works with a PLC digital output (24 V DC impulse) or a panel pushbutton (230 V AC maintained) — no separate contactor needed for the switching function.

Integrated control circuit breakers like the Reflex iC60 are used in control distribution panels to combine branch circuit protection with local on/off switching and remote control via a pulse or maintained signal. Typical applications include HVAC control panels, lighting contactor replacement, pump control, and small machine control where a separate contactor and breaker would take up twice the DIN-rail space.

MPN
A9C64416