Schneider Electric A9CR4240

Schneider Electric A9CR4240 Acti9 REDs RCCB, 40 A, 30 mA, Ty

MPN A9CR4240
Active

Schneider Electric Acti9 REDs, Residual current circuit breaker (RCCB), 2P, 40 A, 30 mA, Type A, 230 V AC, 50 Hz, EN 50557.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9CR4240 specifications
ParameterValue
Control typeToggle
Protection typeRecloser
Voltage230 V AC 50 Hz phase to neutral
Insulation voltage ui500 V
IP ratingIP20
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-5 °C
Storage temperature-40...70 °C
ColorGrey
Depth82 mm
Width54 mm
Height106 mm
Mechanical life cycles4000 cycles open-close
Operating temperature-5...40 °C

Product details

The Schneider Electric A9CR4240 is an Acti9 REDs residual current circuit breaker (RCCB) — a self-reclosing RCCB rated 40 A with 30 mA earth-leakage sensitivity, Type A, 2P, for 230 V AC 50 Hz phase-to-neutral networks. It is designed for TN-S and TT earthing systems as an outgoer device. The 30 mA sensitivity catches leakage paths that would otherwise go undetected until a fault event — standard for personnel protection in IEC 60364 installations.

Reclosing logic and fault handling

The REDs recloser automates the restart cycle after a transient earth fault: reclosing time is 10 s, maximum operational frequency is 30/hour, with a maximum of 3 consecutive restarts and a minimum 180 s interval between two closings. If an insulation fault persists, the cycle stops and the unit waits — it will only restart when the fault becomes transient. This logic is what separates it from a standard RCCB: it avoids nuisance callouts for self-clearing faults (e.g., moisture on a cable gland) while locking out on a hard fault. Insulation fault diagnosis runs every 2 minutes when a fault is detected. The minimum leakage resistance threshold is 16 kOhm during operation, 8 kOhm when non-operating — below that, the recloser holds the circuit open. The manual test function is active above 100 V, so it can be verified in-circuit without a special test set. Local signalling uses a single green/red LED for RCCB ON/OFF and recloser status.

Width 54 mm (3 x 18 mm pitches), height 106 mm, depth 82 mm. Neutral position is left. Wire stripping length 12 mm, tightening torque 3 N·m. IP20 rated — suitable for enclosed panel mounting only; not for wet or outdoor locations without a secondary enclosure.