Schneider Electric A9CR4240 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9CR4240 Acti9 REDs RCCB, 40 A, 30 mA, Ty

MPNA9CR4240
Active

Schneider Electric Acti9 REDs, Residual current circuit breaker (RCCB), 2P, 40 A, 30 mA, Type A, 230 V AC, 50 Hz, EN 50557.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9CR4240 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Local signalling / indication1 LED green/red Residual current device : ON/OFF indication Recloser : ON/OFF indication
A9CR4240 — Electrical Ratings
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)230 V AC 50 Hz phase to neutral
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Mechanical durability (operating cycles)4000 cycles open-close
A9CR4240 — Identification
ParameterValue
Product nameActi9 REDs
Product / component typeResidual current circuit breaker (RCCB)
Device short nameREDs
A9CR4240 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Width in 9 mm modules6
Terminal connectionsGuard tunnel terminal 35 mm² rigid Guard tunnel terminal 35 mm² flexible Guard tunnel terminal 35 mm² flexible with ferrule
Wire stripping length12 mm
Terminal tightening torque3 N.m
Width54 mm
Height106 mm
Depth82 mm
A9CR4240 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9CR4240 — Approvals
ParameterValue
StandardsEN 50557

Product details

The Schneider Electric A9CR4240 is an Acti9 REDs residual current circuit breaker (RCCB) — a self-reclosing RCCB rated 40 A with 30 mA earth-leakage sensitivity, Type A, 2P, for 230 V AC 50 Hz phase-to-neutral networks. It is designed for TN-S and TT earthing systems as an outgoer device. The 30 mA sensitivity catches leakage paths that would otherwise go undetected until a fault event — standard for personnel protection in IEC 60364 installations.

Reclosing logic and fault handling

The REDs recloser automates the restart cycle after a transient earth fault: reclosing time is 10 s, maximum operational frequency is 30/hour, with a maximum of 3 consecutive restarts and a minimum 180 s interval between two closings. If an insulation fault persists, the cycle stops and the unit waits — it will only restart when the fault becomes transient. This logic is what separates it from a standard RCCB: it avoids nuisance callouts for self-clearing faults (e.g., moisture on a cable gland) while locking out on a hard fault. Insulation fault diagnosis runs every 2 minutes when a fault is detected. The minimum leakage resistance threshold is 16 kOhm during operation, 8 kOhm when non-operating — below that, the recloser holds the circuit open. The manual test function is active above 100 V, so it can be verified in-circuit without a special test set. Local signalling uses a single green/red LED for RCCB ON/OFF and recloser status.

Width 54 mm (3 x 18 mm pitches), height 106 mm, depth 82 mm. Neutral position is left. Wire stripping length 12 mm, tightening torque 3 N·m. IP20 rated — suitable for enclosed panel mounting only; not for wet or outdoor locations without a secondary enclosure.

Frequently asked questions

What is the rated current and earth leakage sensitivity of the A9CR4240?

40 A rated current with 30 mA earth-leakage sensitivity, Type A, 2P.

What standards does the A9CR4240 comply with?

It is designed to EN 50557 (requirements for automatic reclosing devices for RCCBs).