Skip to main content
Schneider Electric A9D34840

A9D34840 Acti9 iC60H RCBO, 1P+N 40A B-Curve 30mA 10kA

MPN A9D34840
Obsolete

Schneider Electric Acti9 iC60H RCBO, 1P+N, 40 A rated current at 50 °C, B-curve, 30 mA earth-leakage sensitivity, 10 kA breaking capacity at 240 V AC, thermal-magnetic trip, DIN-rail clip-on mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D34840 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230/240 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-15 °C
Storage temperature-40...85 °C
ColorWhite
Depth77.5 mm
Width18 mm
Height110 mm
Electrical life cycles5000 cycles
Mechanical life cycles20000 cycles
Operating temperature-15...60 °C

Product details

It carries a 40 A rated current at 50 °C, B-curve trip characteristic, and 30 mA earth-leakage sensitivity. The breaking capacity is 10 kA Icn at 240 V AC, 50/60 Hz, which means it can safely interrupt fault currents up to that level on a 240 V single-phase circuit without welding contacts or cascading upstream. The thermal-magnetic trip unit handles both overload (thermal bimetal) and short-circuit (magnetic solenoid) protection in one device.

The 30 mA earth-leakage sensitivity provides personal protection against direct contact — standard for socket-outlet circuits in most domestic and commercial TN earthing systems. The device is suitable for isolation and has a contact position indicator — green/red flag visible through the front window — so you can verify the contacts are open without relying on the toggle position alone.

Integration notes

Neutral is on the left, which matters for busbar orientation in a single-phase board. Screw-clamp terminals: top accepts 1–25 mm² rigid or 1–16 mm² flexible; bottom accepts 1–16 mm² rigid or 1–10 mm² flexible. Wire stripping length: 14 mm for the top connection, 13 mm for the bottom. The device is padlockable with a 4 mm diameter padlock for lockout/tagout. The outgoer position means it's intended for final subcircuit protection, not as a main switch.

MPN
A9D34840