Skip to main content
Schneider Electric A9D53632

Schneider A9D53632 Acti9 iDPN Vigi 32A C-Curve 30mA RCBO

MPN A9D53632
Obsolete

Schneider Electric Acti9 iDPN Vigi RCBO, 1P+N, 32 A, C-curve, 30 mA earth leakage, 6 kA breaking capacity, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D53632 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230...240 V AC 50 Hz
Insulation voltage ui400 V AC 50 Hz
Breaking capacity6000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9D53632 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width36 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9D53632 is an Acti9 iDPN Vigi residual-current circuit breaker (RCBO) — one module wide, combining overcurrent and earth-leakage protection in a single 1P+N package. Rated 32 A with a C-curve magnetic trip (5–10 × In) and 30 mA earth-leakage sensitivity, it's sized for final subcircuits in residential or light-commercial distribution boards where you need both short-circuit and personnel protection without stacking separate devices.

The 6000 A Icn breaking capacity at 230–240 V AC (EN/IEC 61009-2-1) covers the vast majority of domestic and small commercial service entrances — it safely interrupts a fault up to that level without welding or exploding. The 30 mA earth-leakage threshold is the standard for personal shock protection; it will catch a live-to-ground fault through a person before ventricular fibrillation current is reached. Thermal-magnetic trip technology gives you a bimetal strip for overload (slow, time-inverse) and a solenoid for short-circuit (instantaneous above the magnetic threshold). That's the workhorse mechanism for this class — no electronics to fail, no auxiliary power needed.

Panel integration

Clips onto standard DIN rail (EN 60715) — 36 mm wide, 85 mm tall, 73 mm deep. The single-pole + neutral layout puts the neutral on the left; the 9 mm connection pitch between phase and neutral matches the Acti9 busbar system. Terminals accept 1–16 mm² rigid or 1–10 mm² flexible, with a 15 mm strip length and 2 N·m tightening torque.

MPN
A9D53632