A9D53640 Acti9 iDPN Vigi MCB, 40A C-curve, 6kA, 100mA RCD

MPN A9D53640
Active

Schneider Electric Acti9 iDPN Vigi, RCBO, 1P+N, 40 A, C-curve, 6 kA breaking capacity, 100 mA earth leakage, DIN rail clip-on, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D53640 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230...240 V AC 50 Hz
Insulation voltage ui400 V AC 50 Hz
Breaking capacity6000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9D53640 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width36 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

It protects a single outgoing final circuit against overload, short-circuit (thermal-magnetic trip, C-curve 5...10 x In), and earth leakage at 100 mA sensitivity. Rated 40 A with 6 kA breaking capacity at 230...240 V AC, 50 Hz, it clips onto a DIN rail and is intended for distribution boards in residential or light commercial installations.

The 40 A rated current and C-curve (5–10 x In magnetic trip) means this RCBO is sized for general-purpose resistive and moderate inductive loads — lighting, socket outlets, small appliances — not for motor starting or high-inrush circuits where a D-curve would be needed. Integrated 100 mA earth-leakage protection (sensitivity) provides fire protection and indirect-contact protection, not personal shock protection (that requires 30 mA or lower). Typical placement is as an outgoer in the distribution board, protecting a circuit where the loop impedance or equipment leakage makes a separate RCD + MCB combination desirable.

Clip-on mounting to DIN rail (EN 60715). The module occupies 4 pitches at 9 mm per pole — 36 mm total width. Neutral is on the left. Terminals accept 1–16 mm² rigid or 1–10 mm² flexible (with or without ferrule); strip length 15 mm, tightening torque 2 N.m. IP20 rated (IP40 in modular enclosure).

Limitation class 3 per that standard.

MPN
A9D53640