Skip to main content
Schneider Electric A9D54225

A9D54225 Acti9 iC60 RCBO, 2P, 25 A, C-curve, 300 mA, 10 kA

MPN A9D54225
Obsolete

Schneider Electric Acti9 iC60 RCBO, 2P, 25 A, C-curve, 300 mA earth-leakage sensitivity, 10 kA Icn at 230 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D54225 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage220...240 V AC 50 Hz
Insulation voltage ui500 V AC 50 Hz
Breaking capacity10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 15 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
Terminal pitch9 mm between poles
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
ColorWhite

All specifications

A9D54225 additional specifications
ParameterValue
Depth78 mm
Width36 mm
Height86 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The A9D54225: Rated 10 000 A Icn at 220...240 V AC 50 Hz per EN/IEC 61009-2-1, with an ultimate breaking capacity (Icu) of 15 kA at the same voltage per EN/IEC 60947-2. The Icn figure governs the standard service-breaking duty for the RCBO; the higher Icu gives headroom for fault clearance under industrial fault conditions.

Clip-on mounting to DIN rail (35 mm symmetrical rail per EN 60715). Occupies 4 pitches at 9 mm between poles — 36 mm total width. Tunnel-type terminals accept 1...35 mm² rigid or 1...25 mm² flexible (with or without ferrule); strip length 12 mm, tightening torque 2 N·m. IP40 in a distribution enclosure, IP20 for the terminals — adequate for enclosed panel installation, not for wet-area exposure.

Protection characteristics

Thermal-magnetic trip unit with C-curve (magnetic tripping limit 5...10 x In). The 25 A rated current and 300 mA earth-leakage sensitivity protect a 2-pole outgoing circuit against overload, short-circuit, and earth faults in a single device. Integrated earth-leakage protection eliminates the need for a separate RCCB upstream for that circuit. Local signalling shows ON, OFF, and fault trip status on the toggle.

MPN
A9D54225