Skip to main content
Schneider Electric A9D54225 — Residual Current Breakers (RCCB/RCBO)

A9D54225 Acti9 iC60 RCBO, 2P, 25 A, C-curve, 300 mA, 10 kA

MPNA9D54225
Obsolete

Schneider Electric Acti9 iC60 RCBO, 2P, 25 A, C-curve, 300 mA earth-leakage sensitivity, 10 kA Icn at 230 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D54225 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D54225 — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)220...240 V AC 50 Hz
Poles description2P
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D54225 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60 RCBO
A9D54225 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length12 mm for top or bottom connection
Terminal tightening torque2 N.m
Width36 mm
Height86 mm
Depth78 mm
A9D54225 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529
Relative humidity95 % at 55 °C
Tropicalisation2
A9D54225 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 61009-2-1

Product details

The A9D54225: Rated 10 000 A Icn at 220...240 V AC 50 Hz per EN/IEC 61009-2-1, with an ultimate breaking capacity (Icu) of 15 kA at the same voltage per EN/IEC 60947-2. The Icn figure governs the standard service-breaking duty for the RCBO; the higher Icu gives headroom for fault clearance under industrial fault conditions.

Clip-on mounting to DIN rail (35 mm symmetrical rail per EN 60715). Occupies 4 pitches at 9 mm between poles — 36 mm total width. Tunnel-type terminals accept 1...35 mm² rigid or 1...25 mm² flexible (with or without ferrule); strip length 12 mm, tightening torque 2 N·m. IP40 in a distribution enclosure, IP20 for the terminals — adequate for enclosed panel installation, not for wet-area exposure.

Protection characteristics

Thermal-magnetic trip unit with C-curve (magnetic tripping limit 5...10 x In). The 25 A rated current and 300 mA earth-leakage sensitivity protect a 2-pole outgoing circuit against overload, short-circuit, and earth faults in a single device. Integrated earth-leakage protection eliminates the need for a separate RCCB upstream for that circuit. Local signalling shows ON, OFF, and fault trip status on the toggle.

Frequently asked questions

Where can I buy A9D54225 and how do I get a price?

The A9D54225 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does Schneider Electric provide for A9D54225?

The part carries VDE, IMQ, KEMA-KEUR, and NF quality labels, and is certified to EN/IEC 60947-2 and EN/IEC 61009-2-1. A declaration of conformity covering these standards is available with the shipment.

What is A9D54225's earth-leakage sensitivity?

300 mA, integrated into the RCBO — no separate RCCB required for that circuit.

MPN
A9D54225