Schneider Electric A9D60606

Schneider Electric A9D60606 Acti9 iDPN Vigi, 6A B-curve RCBO

MPN A9D60606
Obsolete

Schneider Electric Acti9 iDPN Vigi RCBO, A9D60606, 6 A rated, B-curve, 6 kA breaking capacity, 100 mA earth leakage, 1P+N, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D60606 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230...240 V AC 50 Hz
Insulation voltage ui400 V AC 50 Hz
Breaking capacity6000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9D60606 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width36 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9D60606 is an Acti9 iDPN Vigi RCBO — a combined miniature circuit breaker and residual-current device in a single 36 mm wide module, 1P+N configuration, rated 6 A with a B-curve trip characteristic and 100 mA earth-leakage sensitivity.

The 6 A rated current (In) and B-curve (magnetic trip at 3 to 5 times In) mean this RCBO is sized for lighting circuits, small appliance loads, or control transformers — not motor or high-inrush loads. The 6 kA breaking capacity (Icn at 230–240 V AC, 50 Hz, per EN/IEC 61009-2-1) is the standard domestic-commercial fault-interrupting rating; it safely clears a short-circuit up to 6 kA without welding the contacts or cascading damage upstream. The 100 mA earth-leakage threshold provides personnel and equipment protection against ground faults, not the 30 mA level used for direct human contact protection — so it suits submain or distribution circuits where a lower sensitivity would cause nuisance tripping. Thermal-magnetic trip technology gives the bimetal overload curve for sustained overcurrents and the solenoid for short-circuit response.

Neutral is on the left, phase on the right — check your busbar orientation before wiring. Terminals accept 1 to 16 mm² rigid or 1 to 10 mm² flexible, with a 15 mm strip length and 2 Nm tightening torque. The 9 mm pitch between phase and neutral terminals is the standard for modular RCBOs in this form factor.