Schneider Electric A9D69616

A9D69616 Acti9 iDPN Vigi 16A Curve B RCBO, 6kA

MPN A9D69616
Obsolete

Schneider Electric Acti9 iDPN Vigi, RCBO, 1P+N, 16 A, Curve B, 300 mA earth leakage, 6 kA Icn, DIN rail, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D69616 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230...240 V AC 50 Hz
Insulation voltage ui400 V AC 50 Hz
Breaking capacity6000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9D69616 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width36 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

It protects a single-phase final subcircuit (1P+N, neutral left) against overload, short-circuit, and earth faults in one compact package that clips onto a DIN rail. The 6 kA Icn breaking capacity at 230–240 V AC, 50 Hz, conforms to EN/IEC 61009-2-1, which is the standard for residual-current-operated circuit breakers with integral overcurrent protection. The integrated earth-leakage protection trips at 300 mA sensitivity — a setting typically used for fire prevention or protection of equipment rather than personal shock protection (which requires 30 mA or lower). This makes the A9D69616 a fit for distribution subcircuits where the downstream RCD is already at 30 mA, or for circuits supplying fixed equipment where a higher leakage threshold is acceptable.

The 16 A rated current (In) sets the continuous load limit. In a domestic or light commercial distribution board with a typical upstream transformer impedance, 6 kA is adequate for most final subcircuits. The thermal-magnetic trip unit combines a bimetal strip for overload protection (thermal, time-delayed) and a solenoid for short-circuit protection (magnetic, instantaneous).

Mounting and wiring in the enclosure

Clip-on mounting on a DIN rail, 36 mm wide (4 modules at 9 mm pitch). Connection pitch is 9 mm between phase and neutral terminals, matching standard RCBO busbar spacing. Terminals accept 1 to 16 mm² rigid cable, or 1 to 10 mm² flexible (with or without ferrule). Wire stripping length is 15 mm. IP20 on the front (finger-safe), IP40 inside the modular enclosure once the cover is on.