Schneider Electric A9D87420

A9D87420 Acti9 iC60 RCBO, 4P, 20 A, 30 mA, Curve B, 6 kA

MPN A9D87420
Active

Schneider Electric Acti9 iC60 RCBO, 4P, 20 A, 30 mA, curve B, 6 kA, 4 protected poles, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D87420 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage380...415 V AC 50 Hz
Insulation voltage ui500 V AC 50 Hz
Breaking capacity6000 A Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 6 kA Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2
Terminal pitch9 mm between poles
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
ColorWhite

All specifications

A9D87420 additional specifications
ParameterValue
Depth78 mm
Width72 mm
Height86 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The A9D87420 is a 4-pole Acti9 iC60 RCBO — a combined miniature circuit breaker and residual-current device in one 72 mm wide DIN-rail module. It protects a 4-wire outgoing circuit against overload, short-circuit (curve B, 3 to 5 times In magnetic trip), and earth leakage at 30 mA sensitivity. The 6 kA breaking capacity at 380–415 V AC meets EN/IEC 60947-2 and EN/IEC 61009-2-1, so it's rated for distribution boards in commercial and light industrial panels where the prospective fault current stays under that level.

Rated 20 A with a thermal-magnetic trip unit — the thermal element handles sustained overloads, the magnetic element clears short-circuits above 60 A (3–5 × In). The 30 mA residual-current sensitivity is the standard for personnel protection in most IEC 60364 installations; it trips on leakage to earth, not on line-to-neutral faults. That's adequate for most sub-distribution boards fed by a transformer or a main breaker with a lower let-through. Limitation class 1 per EN/IEC 61009-2-1 means it lets through the full prospective current during a short-circuit — it does not current-limit like a higher-class MCB. That matters for downstream equipment with limited short-circuit withstand; you'd coordinate it with an upstream current-limiting device if the load is sensitive.

Clip-on mount to standard 35 mm DIN rail. The 72 mm width (8 × 9 mm pitches) means it occupies four 18 mm modular spaces — plan your rail fill accordingly. The 9 mm pole-to-pole pitch matches the Acti9 busbar system, so you can feed it with a pre-wired distribution bar without individual ring-tongue terminations. IP40 in the distribution enclosure keeps dust out; IP20 on the terminals is standard for touch-safe finger protection.

The Acti9 iC60 series is a broad, widely stocked platform, so this 4P 20 A 30 mA variant is a standard catalogue item.

MPN
A9D87420