Skip to main content
Schneider Electric A9DC8620

Schneider Electric A9DC8620 Acti9 iCV40H RCBO, 20A C-curve,

MPN A9DC8620
Active

Schneider Electric Acti9 iCV40H RCBO, 1P+N, 20 A, C-curve, 300 mA earth leakage, 10 kA breaking capacity, DIN rail mount, EN/IEC 61009-2-1.

$228.20 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9DC8620 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz
Breaking capacity10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9DC8620 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width36 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

Schneider Electric A9DC8620 Acti9 iCV40H — RCBO with integrated earth-leakage protection

The A9DC8620 is a Schneider Electric Acti9 iCV40H residual current circuit breaker with overcurrent protection (RCBO), combining a 20 A thermal-magnetic trip (C-curve, 5–10× In magnetic tripping limit) with integrated 300 mA earth-leakage protection in a single 1P+N module. It is rated for 10 000 A Icn breaking capacity at 230 V AC, 50/60 Hz, per EN/IEC 61009-2-1, and carries Limitation Class 3 for energy let-through under short-circuit conditions. This is a current-production part (lifecycle stage: current) with VDE and EAC quality labels, designed for distribution outgoer circuits in residential and commercial final-distribution boards. It clips onto a DIN rail (4 x 9 mm pitches wide) and occupies a single modular width, with the neutral on the left and tunnel-type terminals accepting 1–16 mm² rigid or 1–10 mm² flexible conductors.

The 20 A rated current with C-curve (5–10× In magnetic trip) means this RCBO is sized for general-purpose circuits with moderate inrush — lighting banks, socket outlets, small motor loads — where the short magnetic delay avoids nuisance tripping on startup. The 300 mA earth-leakage sensitivity is a protection level typically specified for circuits where 30 mA is too sensitive (e.g., fixed equipment with natural leakage) but where personnel protection is still needed; it is not a 30 mA life-safety device. The 10 kA breaking capacity at 230 V AC (Icn per EN/IEC 61009-2-1) tells you this device can safely interrupt a fault current up to 10 000 A without welding its contacts or rupturing the enclosure — sufficient for most residential and light commercial distribution boards where the prospective short-circuit current at the outgoer is below that threshold. Limitation Class 3 means it restricts let-through energy under short-circuit, reducing stress on downstream wiring and connected equipment.

Tunnel-type terminals accept 1–16 mm² rigid or 1–10 mm² flexible wire; strip length is 14 mm; tightening torque is 2 N·m top or bottom. IP20 (finger-safe) per IEC 60529 for the device body; IP40 for the modular enclosure when installed in a panel. The toggle control provides ON/OFF and fault indication locally. Operating altitude is rated to 2000 m; relative humidity tolerance is 95% at 55 °C.

MPN
A9DC8620