Schneider Electric A9DC8620 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DC8620 Acti9 iCV40H RCBO, 20A C-curve,

MPNA9DC8620
Active

Schneider Electric Acti9 iCV40H RCBO, 1P+N, 20 A, C-curve, 300 mA earth leakage, 10 kA breaking capacity, DIN rail mount, EN/IEC 61009-2-1.

$228.20Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9DC8620 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication Fault indication
A9DC8620 — Electrical Ratings
ParameterValue
Rated current (In)20 A
Rated operational voltage (Ue)230 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability20000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DC8620 — Identification
ParameterValue
Product nameActi9 iCV40
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiCV40H
A9DC8620 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width36 mm
Height85 mm
Depth73 mm
A9DC8620 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity95 % at 55 °C
Operating altitude2000 m
A9DC8620 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

Schneider Electric A9DC8620 Acti9 iCV40H — RCBO with integrated earth-leakage protection

The A9DC8620 is a Schneider Electric Acti9 iCV40H residual current circuit breaker with overcurrent protection (RCBO), combining a 20 A thermal-magnetic trip (C-curve, 5–10× In magnetic tripping limit) with integrated 300 mA earth-leakage protection in a single 1P+N module. It is rated for 10 000 A Icn breaking capacity at 230 V AC, 50/60 Hz, per EN/IEC 61009-2-1, and carries Limitation Class 3 for energy let-through under short-circuit conditions. This is a current-production part (lifecycle stage: current) with VDE and EAC quality labels, designed for distribution outgoer circuits in residential and commercial final-distribution boards. It clips onto a DIN rail (4 x 9 mm pitches wide) and occupies a single modular width, with the neutral on the left and tunnel-type terminals accepting 1–16 mm² rigid or 1–10 mm² flexible conductors.

The 20 A rated current with C-curve (5–10× In magnetic trip) means this RCBO is sized for general-purpose circuits with moderate inrush — lighting banks, socket outlets, small motor loads — where the short magnetic delay avoids nuisance tripping on startup. The 300 mA earth-leakage sensitivity is a protection level typically specified for circuits where 30 mA is too sensitive (e.g., fixed equipment with natural leakage) but where personnel protection is still needed; it is not a 30 mA life-safety device. The 10 kA breaking capacity at 230 V AC (Icn per EN/IEC 61009-2-1) tells you this device can safely interrupt a fault current up to 10 000 A without welding its contacts or rupturing the enclosure — sufficient for most residential and light commercial distribution boards where the prospective short-circuit current at the outgoer is below that threshold. Limitation Class 3 means it restricts let-through energy under short-circuit, reducing stress on downstream wiring and connected equipment.

Tunnel-type terminals accept 1–16 mm² rigid or 1–10 mm² flexible wire; strip length is 14 mm; tightening torque is 2 N·m top or bottom. IP20 (finger-safe) per IEC 60529 for the device body; IP40 for the modular enclosure when installed in a panel. The toggle control provides ON/OFF and fault indication locally. Operating altitude is rated to 2000 m; relative humidity tolerance is 95% at 55 °C.

Frequently asked questions

What is the breaking capacity of the A9DC8620?

The A9DC8620 has a breaking capacity of 10 000 A Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1. This is sufficient for most residential and light commercial final-distribution boards.

What earth-leakage sensitivity does the A9DC8620 provide?

The A9DC8620 has integrated earth-leakage protection with a sensitivity of 300 mA. This is a protection level for circuits with natural leakage where 30 mA would cause nuisance tripping, not a 30 mA life-safety device.

What is the A9DC8620's rated current and trip curve?

The A9DC8620 is rated at 20 A with a C-curve (magnetic tripping limit of 5–10× In). It uses thermal-magnetic trip technology, suitable for general-purpose circuits with moderate inrush currents.

Where can I buy the A9DC8620 and what is the lead time?

The A9DC8620 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead-time and price quote.

What compliance documentation does Schneider provide for the A9DC8620?

The A9DC8620 carries VDE and EAC quality labels and is designed to EN/IEC 61009-2-1. It is rated for pollution degree 3 and overvoltage category III per IEC 60364. For RoHS, REACH, or UL documentation, the manufacturer's compliance declarations are available on request.

MPN