Skip to main content
Schneider Electric A9DF3716

Schneider Electric A9DF3716 Acti9 iCV40 RCBO, 16 A, 30 mA, C

MPN A9DF3716
Active

Schneider Electric Acti9 iCV40 RCBO, A9DF3716, 3P+N, 16 A, C-curve, 30 mA earth leakage, 6 kA Icn at 400 V AC.

$267.25 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9DF3716 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz
Breaking capacity6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Terminal pitch18 mm between phases 9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9DF3716 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width90 mm
Height93 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9DF3716 is an Acti9 iCV40 residual current circuit breaker with overcurrent protection (RCBO) — 3P+N, 16 A rated current, C-curve, 30 mA earth leakage sensitivity. Breaking capacity is 6 kA Icn at 400 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1.

The 16 A rating and C-curve (5–10× In magnetic trip) suit general-purpose lighting and socket-outlet circuits where inrush from small motors or capacitive loads is moderate — not for heavy motor starts where a D-curve would be needed. The 30 mA earth leakage sensitivity is the standard for personal protection against indirect contact in residential and commercial final circuits per IEC 60364. The limitation class 3 (EN/IEC 61009-2-1) means the let-through energy is low enough to allow downstream selectivity with a higher-rated upstream device — useful in multi-level distribution.

Clip-on DIN rail mount, 90 mm wide × 93 mm high × 73 mm deep — occupies 10 module pitches. Neutral is on the left. Tunnel-type terminals accept 1–16 mm² rigid or 1–10 mm² flexible cable; tightening torque is 2 N·m. IP20 on the body, IP40 inside a modular enclosure. Mechanical and electrical durability both rated at 20,000 cycles.

MPN