Skip to main content
Schneider Electric A9DG2616

Schneider Electric A9DG2616 Acti9 iCV40 RCBO, 16A, 30mA, B-C

MPN A9DG2616
Active

Schneider Electric Acti9 iCV40 RCBO, 1P+N, 16 A, 30 mA, B-curve, 4500 A, DIN rail.

$168.53 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9DG2616 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz
Breaking capacity4500 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9DG2616 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width36 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9DG2616 is an Acti9 iCV40 RCBO — a combined residual-current circuit breaker with overcurrent protection in a single 36 mm-wide, 1P+N module. Breaking capacity is 4500 A Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1.

The 16 A rated current (In) sets the continuous load limit for the outgoing circuit — size your downstream conductors and loads to stay under this. The 30 mA earth-leakage threshold provides personal protection against direct contact; it is the standard sensitivity for socket-outlet circuits in many domestic and commercial installations. The B-curve (3–5 x In magnetic trip) means the breaker will hold through mild motor inrush or capacitive loads but trips quickly on a hard short — a good match for lighting, small appliances, and general-purpose outlets where the load profile is predictable. In a distribution board, this limits where the RCBO can be placed downstream of a larger upstream breaker or fuse that clips the prospective fault current below 4.5 kA. Thermal-magnetic trip technology means the thermal element handles sustained overloads (slow, heat-dependent) while the magnetic coil reacts to short-circuit currents. The 20000-cycle electrical and mechanical endurance is typical for this class of RCBO — adequate for normal switching duty in a distribution board, but not intended for frequent load-break applications like motor starting.

Tunnel-type terminals accept 1 to 16 mm² rigid or 1 to 10 mm² flexible cable; strip 14 mm and tighten to 2 N·m.

MPN
A9DG2616