Skip to main content
Schneider Electric A9F03216

Schneider Electric A9F03216 Acti9 iC60N MCB, 16A Curve B 2P

MPN A9F03216
Active

Schneider Electric Acti9 iC60N miniature circuit breaker, A9F03216, 16 A rated current, curve B, 2-pole, 36 kA Icu breaking capacity at 12-133 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F03216 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F03216 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F03216 is a 2-pole Acti9 iC60N miniature circuit breaker rated at 16 A with a B-curve trip characteristic. It's not the right curve for motor starting or transformer primaries; those want a C or D curve to ride through the magnetizing inrush. Breaking capacity is the headline number here: 36 kA Icu at 12-133 V AC, 20 kA at 220-240 V, and 10 kA at 380-415 V (per EN/IEC 60947-2).

Snaps onto DIN rail (mounting support: DIN rail). Strip length 14 mm.

Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/commercial). Rated insulation voltage 500 V AC. Pollution degree 3, overvoltage category IV. Suitability for isolation confirmed per both standards. Thermal-magnetic trip unit, 10,000 electrical cycles, 20,000 mechanical cycles.