Skip to main content
Schneider Electric A9F03216 — 2-Pole MCB (DIN Rail)

Schneider Electric A9F03216 Acti9 iC60N MCB, 16A Curve B 2P

MPNA9F03216
Active

Schneider Electric Acti9 iC60N miniature circuit breaker, A9F03216, 16 A rated current, curve B, 2-pole, 36 kA Icu breaking capacity at 12-133 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9F03216 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameIC60N
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F03216 — Electrical
ParameterValue
Rated current [In]16 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)DC AC
Network frequency50/60 Hz
A9F03216 — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit4 x In +/- 20 %
Breaking capacity (Icu)36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9F03216 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F03216 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9F03216 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F03216 is a 2-pole Acti9 iC60N miniature circuit breaker rated at 16 A with a B-curve trip characteristic. It's not the right curve for motor starting or transformer primaries; those want a C or D curve to ride through the magnetizing inrush. Breaking capacity is the headline number here: 36 kA Icu at 12-133 V AC, 20 kA at 220-240 V, and 10 kA at 380-415 V (per EN/IEC 60947-2).

Snaps onto DIN rail (mounting support: DIN rail). Strip length 14 mm.

Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/commercial). Rated insulation voltage 500 V AC. Pollution degree 3, overvoltage category IV. Suitability for isolation confirmed per both standards. Thermal-magnetic trip unit, 10,000 electrical cycles, 20,000 mechanical cycles.

Frequently asked questions

Where can I buy the A9F03216 and get a price?

The A9F03216 is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is the breaking capacity of the A9F03216?

36 kA Icu at 12-133 V AC, 20 kA at 220-240 V, 10 kA at 380-415 V, and 6 kA Icn at 400 V per EN/IEC 60898-1.

What compliance documentation does Schneider provide for the A9F03216?

The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1, with tropicalisation class 2 per IEC 60068-1. It carries IP20 protection and is rated for isolation per both standards.

MPN
A9F03216