Skip to main content
Schneider Electric A9F03232

Schneider Electric A9F03232 Acti9 iC60N MCB, 32 A, 2P, Curve

MPN A9F03232
Active

Schneider Electric Acti9 iC60N, A9F03232, miniature circuit-breaker, 32 A, 2-pole, curve B, 36 kA Icu at 12-133 V AC, DIN rail mount, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F03232 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F03232 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

Miniature circuit-breaker, 32 A, 2-pole, curve B

The Schneider Electric A9F03232 is an Acti9 iC60N miniature circuit-breaker rated 32 A with 2 protected poles and a B tripping curve (4 x In magnetic trip, ±20 %). It carries a 36 kA Icu breaking capacity at 12–133 V AC and 20 kA Icu at 220–240 V AC, both per EN/IEC 60947-2, plus a 10 kA Icn at 400 V AC per EN/IEC 60898-1. That dual-standard rating means it can serve as a branch-circuit protective device under 60947-2 for industrial panels or as a final-subcircuit MCB under 60898-1 for distribution boards — same part, different passport. The thermal-magnetic trip unit handles overloads and short-circuits. Overvoltage category IV and pollution degree 3 ratings confirm it is designed for main panel installation, not downstream subpanels.

The double terminal accepts 1–35 mm² rigid or 1–25 mm² flexible on top or bottom; strip length is 14 mm. A visible trip indicator and contact position indicator give local status without needing to remove the cover. The toggle control is manual on-off, with a separate earth-leakage block available as an add-on (not integrated).

This is a standard catalogue item from Schneider Electric's Acti9 range. For volume or scheduled releases, a blanket PO with release dates typically secures better lead-time consistency.

MPN
A9F03232