Schneider Electric A9F03250

Schneider Electric A9F03250 Acti9 iC60N MCB, 50 A, B Curve,

MPN A9F03250
Active

Schneider Electric Acti9 iC60N, miniature circuit-breaker, A9F03250, 50 A, B curve, 2 poles, 36 kA Icu at 12–133 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F03250 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F03250 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F03250 is an Acti9 iC60N miniature circuit-breaker (MCB) rated 50 A, B curve, 2 poles. Breaking capacity is the headline: 36 kA Icu at 12–133 V AC, 20 kA at 220–240 V, 10 kA at 380–415 V, and 6 kA at 440 V (per IEC 60947-2). Under IEC 60898-1 it is rated 10 kA Icn at 400 V. That means this 50 A MCB can interrupt a 36 kA fault on a low-voltage secondary — useful on high-fault panels where a standard 10 kA breaker would need upstream fusing.

Mounts on DIN rail (EN 60715) — 36 mm wide (4 x 9 mm pitches). Wire strip length 14 mm, tightening torque 3.5 N·m. Thermal-magnetic trip unit with B curve: magnetic tripping limit 4 x In (±20 %), so it holds 200 A peak and trips on moderate overloads — typical for lighting, residential, and general-purpose distribution where inrush is low.

MPN