Skip to main content
Schneider Electric A9F03250 — 2-Pole MCB (DIN Rail)

Schneider Electric A9F03250 Acti9 iC60N MCB, 50 A, B Curve,

MPNA9F03250
Active

Schneider Electric Acti9 iC60N, miniature circuit-breaker, A9F03250, 50 A, B curve, 2 poles, 36 kA Icu at 12–133 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9F03250 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameIC60N
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F03250 — Electrical
ParameterValue
Rated current [In]50 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)DC AC
Network frequency50/60 Hz
A9F03250 — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit4 x In +/- 20 %
Breaking capacity (Icu)36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9F03250 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F03250 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9F03250 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F03250 is an Acti9 iC60N miniature circuit-breaker (MCB) rated 50 A, B curve, 2 poles. Breaking capacity is the headline: 36 kA Icu at 12–133 V AC, 20 kA at 220–240 V, 10 kA at 380–415 V, and 6 kA at 440 V (per IEC 60947-2). Under IEC 60898-1 it is rated 10 kA Icn at 400 V. That means this 50 A MCB can interrupt a 36 kA fault on a low-voltage secondary — useful on high-fault panels where a standard 10 kA breaker would need upstream fusing.

Mounts on DIN rail (EN 60715) — 36 mm wide (4 x 9 mm pitches). Wire strip length 14 mm, tightening torque 3.5 N·m. Thermal-magnetic trip unit with B curve: magnetic tripping limit 4 x In (±20 %), so it holds 200 A peak and trips on moderate overloads — typical for lighting, residential, and general-purpose distribution where inrush is low.

Frequently asked questions

What is the breaking capacity of A9F03250 at 400 V?

Under EN/IEC 60947-2 it is 10 kA Icu at 380–415 V AC; under EN/IEC 60898-1 it is 10 kA Icn at 400 V AC.

Where can I buy A9F03250 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What standards does A9F03250 comply with?

It is dual-rated to EN/IEC 60947-2 and EN/IEC 60898-1, and carries IP20 protection per IEC 60529.

MPN