Schneider A9F03410 Acti9 iC60N MCB, 4P B-Curve 10 A, 36 kA

MPN A9F03410
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, 4P, B-curve, 10 A, 36 kA Icu at 133 V AC, DIN rail mount, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F03410 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F03410 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F03410 is a Schneider Acti9 iC60N miniature circuit breaker — 4 poles, B-curve, rated 10 A. It is a current-production part (lifecycle stage: current). The B-curve means magnetic tripping occurs at 4 x In ±20% (40 A nominal, 32–48 A window), suited for resistive or general-purpose loads where inrush is low — think lighting, heater banks, or control transformers. The 36 kA Icu at 12–133 V AC (EN/IEC 60947-2) is the maximum short-circuit current it can safely interrupt once; at 220–240 V that drops to 20 kA, and at 380–415 V to 10 kA. For a 400 V distribution board the IEC 60898-1 Icn is 6 kA — the more common rating for domestic/commercial final circuits.

Snaps onto DIN rail (mounting support: DIN rail). Occupies 8 x 9 mm pitches = 72 mm width. The 78.5 mm depth and 91 mm height are standard for the iC60 family — no gland-plate surprises. IP20 finger-safe front, pollution degree 3 (conductive pollution expected in industrial enclosures). Overvoltage category IV means it can be installed at the service entrance or main distribution board, not just downstream sub-panels.

Suitability for isolation confirmed under both standards — the contact position indicator shows open/closed state. The part carries CE marking for the EU market; UL/CSA listing is not stated in the evidence, so for North American projects verify local acceptance. RoHS and REACH compliance documentation is available from the manufacturer upon request — standard for Schneider's Acti9 range.