Skip to main content
Schneider Electric A9F03410 — Miniature Circuit Breakers (MCB)

Schneider A9F03410 Acti9 iC60N MCB, 4P B-Curve 10 A, 36 kA

MPNA9F03410
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, 4P, B-curve, 10 A, 36 kA Icu at 133 V AC, DIN rail mount, white.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F03410 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F03410 — Ratings
ParameterValue
Rated current (In)10 A
Poles configuration4P
Number of protected poles4
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F03410 — Protection
ParameterValue
Curve codeB
Trip unit technologyThermal-magnetic
Magnetic tripping limit4 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F03410 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8
A9F03410 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F03410 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F03410 is a Schneider Acti9 iC60N miniature circuit breaker — 4 poles, B-curve, rated 10 A. It is a current-production part (lifecycle stage: current). The B-curve means magnetic tripping occurs at 4 x In ±20% (40 A nominal, 32–48 A window), suited for resistive or general-purpose loads where inrush is low — think lighting, heater banks, or control transformers. The 36 kA Icu at 12–133 V AC (EN/IEC 60947-2) is the maximum short-circuit current it can safely interrupt once; at 220–240 V that drops to 20 kA, and at 380–415 V to 10 kA. For a 400 V distribution board the IEC 60898-1 Icn is 6 kA — the more common rating for domestic/commercial final circuits.

Snaps onto DIN rail (mounting support: DIN rail). Occupies 8 x 9 mm pitches = 72 mm width. The 78.5 mm depth and 91 mm height are standard for the iC60 family — no gland-plate surprises. IP20 finger-safe front, pollution degree 3 (conductive pollution expected in industrial enclosures). Overvoltage category IV means it can be installed at the service entrance or main distribution board, not just downstream sub-panels.

Suitability for isolation confirmed under both standards — the contact position indicator shows open/closed state. The part carries CE marking for the EU market; UL/CSA listing is not stated in the evidence, so for North American projects verify local acceptance. RoHS and REACH compliance documentation is available from the manufacturer upon request — standard for Schneider's Acti9 range.

Frequently asked questions

What is the closest alternative to A9F03410 in the Acti9 family?

Within the Acti9 iC60N range, the closest sibling differs only by curve or poles — e.g., a C-curve variant (A9F04410) for motor or transformer loads with higher inrush. No pin-compatible drop-in exists across families; the iC60N footprint is shared across all B/C/D curves and pole counts within the series.

What compliance documentation does Schneider provide for A9F03410?

The breaker is dual certified to EN/IEC 60947-2 and EN/IEC 60898-1, carries CE marking, and meets tropicalisation class 2 per IEC 60068-1. RoHS/REACH declarations are available from Schneider on request.

MPN