Skip to main content
Schneider Electric A9F03606

A9F03606 Acti9 iC60N MCB, 6 A, 1P+N, Curve B, 36 kA

MPN A9F03606
Active

Schneider Electric Acti9 iC60N miniature circuit-breaker, A9F03606, 6 A rated, 1P+N, curve B, 36 kA breaking capacity at 12-60 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F03606 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F03606 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F03606 is an Acti9 iC60N miniature circuit-breaker (MCB) with a 6 A rated current, 1P+N poles, and a B-curve trip characteristic. The B curve means magnetic tripping occurs at 4 x In (±20 %) — so at roughly 24 A fault current the breaker clears fast, making it a good fit for resistive loads like lighting or small heaters where inrush is low. The breaking capacity hits 36 kA Icu at 12...60 V AC (EN/IEC 60947-2) and 10 kA Icu at 220...240 V AC; the IEC 60898-1 rating is 6000 A Icn at 230 V AC — enough for most residential and light commercial distribution boards.

Snaps onto a DIN rail (mounting support: DIN rail). At 36 mm wide (4 x 9 mm pitches), it occupies two standard module spaces in the enclosure. Terminals accept 1...25 mm² rigid or 1...16 mm² flexible wire; strip length is 14 mm. IP20 rated — fine for dry indoor panels, not for washdown or outdoor use.

Pollution degree 3 (industrial environment). Overvoltage category IV. Utilisation category A.

Durability and environmental

Rated for 10,000 electrical cycles and 20,000 mechanical cycles. The thermal-magnetic trip unit covers both overload and short-circuit protection. Separate earth-leakage protection block can be added if needed.

MPN
A9F03606