Skip to main content
Schneider Electric A9F03610

Schneider Electric A9F03610 Acti9 iC60N MCB, 10 A, 1P+N, B C

MPN A9F03610
Active

Schneider Electric Acti9 iC60N, A9F03610, miniature circuit breaker, 1P+N, 10 A, B-curve, 36 kA breaking capacity at 12-60 VAC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F03610 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9F03610 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F03610 is an Acti9 iC60N miniature circuit breaker — 1P+N, 10 A rated, B-curve, thermal-magnetic trip. It's a current-production distribution breaker (lifecycle stage: current) built for DIN-rail panels where you need a switched neutral and a single protected pole.

This breaker carries a 36 kA Icu at 12-60 V AC (EN/IEC 60947-2), 20 kA at 100-133 V, and 10 kA at 220-240 V. Under the residential-standard EN/IEC 60898-1 it's rated 6000 A Icn at 230 V. The dual-standard rating (60947-2 for industrial, 60898-1 for domestic) gives you flexibility in specification: you can use it in a distribution board or an industrial sub-panel.

Trip curve and coordination

B-curve means magnetic trip at 4 x In (40 A, +/-20%). For motor or drive circuits you'd typically step to C or D curve, but for distribution duty this holds selectivity well with upstream C-curve breakers. The thermal-magnetic trip unit gives you inverse-time overload protection (thermal) plus instantaneous short-circuit (magnetic).

Height is 91 mm, depth 78.5 mm — check your gland plate clearance if you're fitting a deep enclosure. Terminals accept 1-25 mm² rigid or 1-16 mm² flexible, double-terminal top and bottom for daisy-chaining. IP20 finger-safe, pollution degree 3 (conductive pollution environment — typical for industrial panels not sealed from the floor).

MPN