Skip to main content
Schneider Electric A9F03710

Schneider Electric A9F03710 Acti9 iC60N MCB, 10 A, B Curve,

MPN A9F03710
Active

Schneider Electric Acti9 iC60N, A9F03710, miniature circuit breaker, 10 A, B curve, 3P+N, 36 kA breaking capacity, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F03710 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F03710 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F03710 is an Acti9 iC60N miniature circuit breaker rated 10 A with a B curve, 3P+N poles, and a thermal-magnetic trip unit. It mounts on a DIN rail and is sized for distribution panels — 72 mm wide, 91 mm tall, 78.5 mm deep — so it occupies a standard 4-module footprint in a consumer unit or sub-distribution board. Rated for AC and DC networks at 50/60 Hz, it carries dual certification to EN/IEC 60898-1 (domestic MCB standard) and EN/IEC 60947-2 (industrial breaker standard), which means it can serve both residential final circuits and industrial control-panel feeder protection.

The headline breaking capacity is 36 kA Icu at 12–133 V AC, dropping to 20 kA at 220–240 V, 10 kA at 380–415 V, and 6 kA at 440 V per IEC 60947-2. Under the domestic MCB standard (IEC 60898-1) it delivers 6000 A Icn at 400 V. The B curve means magnetic tripping occurs at 4 x In (±20 %), so a 10 A breaker trips instantaneously between roughly 32 A and 48 A.

The double-terminal design accepts 1–25 mm² rigid or 1–16 mm² flexible on both top and bottom, with a tightening torque of 2 N·m and a strip length of 14 mm.

MPN
A9F03710