Schneider Electric A9F03710 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F03710 Acti9 iC60N MCB, 10 A, B Curve,

MPNA9F03710
Active

Schneider Electric Acti9 iC60N, A9F03710, miniature circuit breaker, 10 A, B curve, 3P+N, 36 kA breaking capacity, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F03710 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F03710 — Ratings
ParameterValue
Rated current (In)10 A
Poles configuration3P + N
Number of protected poles3
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F03710 — Protection
ParameterValue
Curve codeB
Trip unit technologyThermal-magnetic
Magnetic tripping limit4 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F03710 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8
A9F03710 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F03710 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F03710 is an Acti9 iC60N miniature circuit breaker rated 10 A with a B curve, 3P+N poles, and a thermal-magnetic trip unit. It mounts on a DIN rail and is sized for distribution panels — 72 mm wide, 91 mm tall, 78.5 mm deep — so it occupies a standard 4-module footprint in a consumer unit or sub-distribution board. Rated for AC and DC networks at 50/60 Hz, it carries dual certification to EN/IEC 60898-1 (domestic MCB standard) and EN/IEC 60947-2 (industrial breaker standard), which means it can serve both residential final circuits and industrial control-panel feeder protection.

The headline breaking capacity is 36 kA Icu at 12–133 V AC, dropping to 20 kA at 220–240 V, 10 kA at 380–415 V, and 6 kA at 440 V per IEC 60947-2. Under the domestic MCB standard (IEC 60898-1) it delivers 6000 A Icn at 400 V. The B curve means magnetic tripping occurs at 4 x In (±20 %), so a 10 A breaker trips instantaneously between roughly 32 A and 48 A.

The double-terminal design accepts 1–25 mm² rigid or 1–16 mm² flexible on both top and bottom, with a tightening torque of 2 N·m and a strip length of 14 mm.

Frequently asked questions

What is A9F03710's breaking capacity at 400 V?

Under IEC 60898-1 it is rated 6000 A Icn at 400 V AC; under IEC 60947-2 it delivers 10 kA Icu at 380–415 V AC and 6 kA Icu at 440 V AC.

What compliance documentation does Schneider provide for A9F03710?

The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1, carries IP20 protection per IEC 60529, and is tropicalised to class 2 per IEC 60068-1. Standard CE/UKCA marking applies for EU and UK markets.

MPN
A9F03710