Skip to main content
Schneider Electric A9F03732

Schneider Electric A9F03732 Acti9 iC60N MCB, 32 A, B-Curve,

MPN A9F03732
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, 32 A, B-curve, 3P+N, 36 kA breaking capacity at 133 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F03732 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F03732 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F03732 is a 32 A B-curve miniature circuit breaker from the Acti9 iC60N family, wired as 3P+N. The B-curve (magnetic trip at 4 x In ±20 %) means it trips fast on short-circuit but tolerates modest inrush — suited for resistive or general-purpose distribution loads, not motor starts or transformer banks where a C- or D-curve would be needed to avoid nuisance tripping. The 36 kA Icu at 12–133 V AC is the ultimate breaking capacity under the IEC 60947-2 standard; at 400 V AC the Icn under IEC 60898-1 drops to 6000 A, which is the rating that governs most European distribution panels. The thermal-magnetic trip unit gives both overload (thermal bimetal) and short-circuit (solenoid) protection in one package.

Snaps onto a DIN rail — 9 mm pitch, 8 modules wide (72 mm). The 3P+N configuration puts the neutral on the left, which matters when you're laying out busbars or downstream distribution blocks. Strip length 14 mm. IP20 rated, so it's for inside an enclosure, not washdown. The toggle gives local on/off and a trip indicator shows when it's dropped out — useful for a quick visual sweep of the panel.

Listed as current production. The Acti9 iC60N series is Schneider's mainstream MCB line for commercial and light industrial distribution. No successor or phase-out notice exists.

Dual-rated to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household and similar) — so it qualifies for both a factory distribution board and a building sub-main. Pollution degree 3, overvoltage category IV, suitability for isolation marked on both standards.

MPN
A9F03732