Schneider Electric A9F03732 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F03732 Acti9 iC60N MCB, 32 A, B-Curve,

MPNA9F03732
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, 32 A, B-curve, 3P+N, 36 kA breaking capacity at 133 V AC, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F03732 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F03732 — Ratings
ParameterValue
Rated current (In)32 A
Poles configuration3P + N
Number of protected poles3
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F03732 — Protection
ParameterValue
Curve codeB
Trip unit technologyThermal-magnetic
Magnetic tripping limit4 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F03732 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8
A9F03732 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F03732 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F03732 is a 32 A B-curve miniature circuit breaker from the Acti9 iC60N family, wired as 3P+N. The B-curve (magnetic trip at 4 x In ±20 %) means it trips fast on short-circuit but tolerates modest inrush — suited for resistive or general-purpose distribution loads, not motor starts or transformer banks where a C- or D-curve would be needed to avoid nuisance tripping. The 36 kA Icu at 12–133 V AC is the ultimate breaking capacity under the IEC 60947-2 standard; at 400 V AC the Icn under IEC 60898-1 drops to 6000 A, which is the rating that governs most European distribution panels. The thermal-magnetic trip unit gives both overload (thermal bimetal) and short-circuit (solenoid) protection in one package.

Snaps onto a DIN rail — 9 mm pitch, 8 modules wide (72 mm). The 3P+N configuration puts the neutral on the left, which matters when you're laying out busbars or downstream distribution blocks. Strip length 14 mm. IP20 rated, so it's for inside an enclosure, not washdown. The toggle gives local on/off and a trip indicator shows when it's dropped out — useful for a quick visual sweep of the panel.

Listed as current production. The Acti9 iC60N series is Schneider's mainstream MCB line for commercial and light industrial distribution. No successor or phase-out notice exists.

Dual-rated to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household and similar) — so it qualifies for both a factory distribution board and a building sub-main. Pollution degree 3, overvoltage category IV, suitability for isolation marked on both standards.

Frequently asked questions

What is the breaking capacity of A9F03732 at 400 V?

At 400 V AC under EN/IEC 60898-1 the Icn is 6000 A. Under EN/IEC 60947-2 the Icu is 10 kA at 380–415 V AC and 6 kA at 440 V AC.

What is the closest alternative to A9F03732 in the Acti9 family?

Within the same Acti9 iC60N range, the closest alternative would be a different current rating or curve code — the mechanical footprint and terminal specs are identical across the series. There is no pin-compatible substitute from another manufacturer that matches the dual-standard certification and 3P+N configuration.