Schneider Electric A9F04601

Schneider Electric A9F04601 Acti9 iC60N MCB, 1P+N, 1 A, C-Cu

MPN A9F04601
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, 1P+N, 1 A, C-curve, 50 kA breaking capacity, DIN rail mount, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F04601 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F04601 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F04601 is a 1 A miniature circuit breaker from the Acti9 iC60N series, built for distribution-level protection on DIN-rail panels. It's a 1P+N thermal-magnetic breaker with a C-curve — meaning it trips magnetically at 8 x In (±20 %), so it handles moderate inrush from small motor starters or lighting ballasts without nuisance tripping, but clears a hard short fast.

Breaking capacity and standards

Rated breaking capacity hits 50 kA Icu at 220–240 V AC per IEC 60947-2, and 6 kA Icn at 230 V per IEC 60898-1. That dual-rating means it's certified for both industrial (60947-2) and residential/commercial (60898-1) installations — a single part covers the panel builder's coordination study and the site's wiring rules.

Snaps onto standard DIN rail, occupies 4 x 9 mm pitches (36 mm wide). The neutral is on the left, fixed position; no swapping for reversed-phase panels.