Skip to main content
Schneider Electric A9F04606

A9F04606 Acti9 iC60N MCB, 6 A, C Curve, 1P+N, DIN Rail

MPN A9F04606
Active

Schneider Electric Acti9 iC60N, A9F04606, miniature circuit breaker, 6 A, C curve, 1P+N, 36 kA breaking capacity, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F04606 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F04606 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

Breaking capacity is the headline: 36 kA Icu at 12–60 V AC, 20 kA at 100–133 V AC, and 10 kA at 220–240 V AC per EN/IEC 60947-2, plus 6 kA Icn at 230 V per EN/IEC 60898-1. Thermal-magnetic trip unit, 1P+N configuration (neutral switched, left position), pollution degree 3, overvoltage category IV — this is a main-panel or sub-distribution board MCB, not a final-circuit gadget. The IP20 finger-safe terminals accept 1–25 mm² rigid or 1–16 mm² flexible, double-terminated top and bottom, with 2 N.m torque and 14 mm strip length.

No direct replacement or successor is listed because none is needed — the iC60N platform is the current generation. If you are retrofitting an older Multi9 or C60 series panel, the A9F04606 is the direct functional equivalent with the same 36 mm width per pole and DIN-rail footprint.

The toggle actuator and trip indicator give local status without opening the panel door. Neutral is on the left — wire accordingly if the panel layout has a fixed busbar orientation. Tropicalisation class 2 per IEC 60068-1 and 95% RH at 55 °C rating make it suitable for non-condensing humid environments like pump rooms or outdoor-rated enclosures, though the IP20 body itself is not washdown-rated.

MPN