Schneider Electric A9F04606 — 1-Pole MCB (DIN Rail)

A9F04606 Acti9 iC60N MCB, 6 A, C Curve, 1P+N, DIN Rail

MPNA9F04606
Active

Schneider Electric Acti9 iC60N, A9F04606, miniature circuit breaker, 6 A, C curve, 1P+N, 36 kA breaking capacity, DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9F04606 — Identification
ParameterValue
Product nameActi9 iC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short nameIC60N
Poles description1P + N
Number of protected poles1
Device applicationDistribution
A9F04606 — Electrical & Protection
ParameterValue
Rated current (In)6 A
Tripping curve codeC
Magnetic tripping limit8 x In +/- 20 %
Breaking capacity (Icu / AIR)36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9F04606 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Mounting supportDIN rail
Width36 mm
Height91 mm
Depth78.5 mm
Tightening torque (by circuit)2 N.m top or bottom
A9F04606 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
A9F04606 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2 EN/IEC 60898-1
A9F04606 — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-2

Product details

Breaking capacity is the headline: 36 kA Icu at 12–60 V AC, 20 kA at 100–133 V AC, and 10 kA at 220–240 V AC per EN/IEC 60947-2, plus 6 kA Icn at 230 V per EN/IEC 60898-1. Thermal-magnetic trip unit, 1P+N configuration (neutral switched, left position), pollution degree 3, overvoltage category IV — this is a main-panel or sub-distribution board MCB, not a final-circuit gadget. The IP20 finger-safe terminals accept 1–25 mm² rigid or 1–16 mm² flexible, double-terminated top and bottom, with 2 N.m torque and 14 mm strip length.

No direct replacement or successor is listed because none is needed — the iC60N platform is the current generation. If you are retrofitting an older Multi9 or C60 series panel, the A9F04606 is the direct functional equivalent with the same 36 mm width per pole and DIN-rail footprint.

The toggle actuator and trip indicator give local status without opening the panel door. Neutral is on the left — wire accordingly if the panel layout has a fixed busbar orientation. Tropicalisation class 2 per IEC 60068-1 and 95% RH at 55 °C rating make it suitable for non-condensing humid environments like pump rooms or outdoor-rated enclosures, though the IP20 body itself is not washdown-rated.

Frequently asked questions

Where can I buy the A9F04606 and get a price?

The A9F04606 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of the A9F04606?

36 kA Icu at 12–60 V AC, 20 kA at 100–133 V AC, and 10 kA at 220–240 V AC per EN/IEC 60947-2; 6 kA Icn at 230 V per EN/IEC 60898-1.

What compliance documentation does Schneider provide for the A9F04606?

The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1, with tropicalisation class 2 per IEC 60068-1 and pollution degree 3 per EN/IEC 60947-2. Standard Schneider documentation includes the declaration of conformity and CE marking.

MPN
A9F04606