Schneider Electric A9F05110

Schneider Electric A9F05110 Acti9 iC60N MCB, 10 A, D Curve,

MPN A9F05110
Active

Schneider Electric Acti9 iC60N, miniature circuit-breaker, 1P, 10 A, D curve, 36 kA Icu at 12…60 V AC, DIN rail mount, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05110 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F05110 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F05110 is an Acti9 iC60N miniature circuit breaker — a 1-pole, 10 A thermal-magnetic MCB with a D tripping curve. It's built for distribution duty in a 2-module (18 mm per pole) DIN-rail footprint, so it slots straight into a standard panel enclosure alongside other Acti9 kit.

Breaking capacity — what it means on the line

This breaker carries dual-standard ratings: 36 kA Icu at 12…60 V AC and 10 kA Icu at 220…240 V AC per IEC 60947-2, plus 6 kA Icn at 230 V AC per IEC 60898-1. The 36 kA figure covers low-voltage AC distribution where fault current can spike — think panel feeds close to a transformer. On the DC side, it's rated 15 kA Icu at 12…60 V DC and 10 kA at 60…72 V DC — useful for DC distribution in telecom shelters or control cabinets where battery-backed 48 V loops need short-circuit protection.

Snaps onto a DIN rail (35 mm symmetrical rail per EN 60715).