Specifications

A9F05202 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F05202 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

Rated 2 A continuous, thermal-magnetic trip unit. The magnetic threshold at 12 x In (24 A) handles motor inrush without tripping. Breaking capacity is 50 kA Icu per EN/IEC 60947-2 across 12–415 V AC, and 10 kA Icn per EN/IEC 60898-1 at 400 V — so it's rated for both industrial (60947-2) and domestic (60898-1) standards. Overvoltage category IV means it's suitable for main distribution panels, not just sub-circuits. Pollution degree 3 allows use in environments with conductive dust or humidity. The 2-pole version protects both live and neutral, with a separate earth-leakage block available (not included).

Integration notes

Mounts on DIN rail (EN 60715). Double terminals accept 1–25 mm² rigid or 1–16 mm² flexible wire; tighten to 2 N·m. Strip 14 mm of insulation. The toggle provides manual on/off and a trip indicator shows the breaker has opened on fault. IP20 rated — suitable for enclosed panels only. The white housing and compact 36 mm width (4 modules) fit standard distribution boards.