Skip to main content
Schneider Electric A9F05204

Schneider A9F05204 Acti9 iC60N MCB, 4 A D-curve, 2P

MPN A9F05204
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, A9F05204, 4 A, D-curve, 2-pole, 50 kA breaking capacity at 415 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05204 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F05204 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

What this MCB does on the line

Two poles, thermal-magnetic trip, rated 4 A continuous. The D-curve magnetic trip fires at 12 x In (±20 %), so a 4 A breaker holds through 48 A inrush peaks without nuisance tripping. Breaking capacity: 50 kA Icu at 415 V AC (EN/IEC 60947-2) and 10 kA Icn at 400 V (EN/IEC 60898-1). The dual standard means it qualifies for both industrial distribution panels (60947-2) and final sub-circuits (60898-1) — one part covers both, which simplifies BOM management.

Width is 36 mm (4 x 9 mm pitches), depth 78.5 mm, height 91 mm. That 36 mm footprint for a 2-pole breaker is standard — no surprises when laying out a multi-way distribution board. Tightening torque 2 N·m. Wire strip length 14 mm. IP20 finger-safe terminals — fine for enclosed panels; not rated for wet environments.

Dual-rated to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household/residential). Isolation-capable per both standards. Limitation class 3. Suitability for isolation marked on the device.

MPN
A9F05204